BSSDV - H9728(FM),NICAD BATTERY,SEALED

  • MSDS: BSSDV
  • Manufacturer: ALEXANDER MFG CO
  • Product Name: H9728(FM),NICAD BATTERY,SEALED
  • National Stock Number: 6140-01-292-1093
Product Identification

Product ID:H9728(FM),NICAD BATTERY,SEALED
MSDS Date:01/20/1996
FSC:6140
NIIN:01-292-1093
MSDS Number: BSSDV

Responsible Party
ALEXANDER MFG CO.
1511 S. GARFIELD PL
MASON CITY, IA 50401-5662
US

Emergency Phone: 515-423-8955

Info Phone: 515-423-1161

Cage: 56469

Contractor
ALEXANDER TECHNOLOGIES INC
1508 MASON CITY, IA 50401 US

Telephone: 515-423-1161/8955

Cage: 56469

Ingredients

NICKEL (SARA 313) (CERCLA) INCLUDES INGRED #2

CAS: 7440-02-0

RTECS: QR5950000

Fraction By Weight: 20-30%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3; 9596


NICKEL HYDROXIDE (SARA 313) (CERCLA)

CAS: 12054-48-7

RTECS: QR7040000

Fraction By Weight: SEE #1%

OSHA PEL 1 MG(NI)/M3

ACGIH TLV: 0.1 MG(NI)/M3; 9596

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


CADMIUM (SARA 313) (CERCLA) INCLUDES INGRED #4

CAS: 7440-43-9

RTECS: EU9800000

Fraction By Weight: 13-15%

OSHA PEL 0.2 MG/M3 DUST; Z-2

ACGIH TLV: 0.01 MG/M3 DUST;9596

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


CADMIUM HYDROXIDE

CAS: 21041-95-2

Fraction By Weight: SEE #3%

OSHA PEL 0.05 MG CD/M3

ACGIH TLV: 0.05 MG CD/M3


POTASSIUM HYDROXIDE (CERCLA), AS DRY HYDROXIDE

CAS: 1310-58-3

RTECS: TT2100000

Fraction By Weight: 2-4%

OSHA PEL C 2 MG/M3

ACGIH TLV: C 2 MG/M3; 9596

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NOTE:UNDER NORMAL USE, THE H9728
BATTERY DOES NOT RELEASE TOXIC MATERIAL.INHAL:DURING FIRE INVOLVING
LG QUANT OF BATT CADMIUM FUMES MAY BE RELEASED.EYE/SKIN:IF BATT
RUPTURES SKIN CONTACT MAY COME IN C ONTACT W/TRACE AMT OF POTASSIUM
HYDROXIDE WILL CAUSE BURN.INGEST:NA.
Explanation of Carcinogenicity:PER MSDS:CHEM LISTED AS CARC OR POT
CARC:NO INFO AVAILABLE.NTP/IARC/OSHA:NO. HMIS:CADMIUM & NICKEL
PRESENT.

First Aid

First Aid:NONE SPECIFIED BY MANUFACTURER. HMIS:FOLLOW APPLICABLE
AMERICAN RED CROSS 1STAID PROCEDURES. SEE DOCTOR.

Fire Fighting

Flash Point:NO INFO AVAI
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:NO INFO AVAI
Upper Limits:NO INFO AVAI
Extinguishing Media:NO INFO AVAILABLE
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS IF
LARGE QUANTITIES OF BATTERIES ARE ON FIRE.WAREHOUSE OR DEPOT TYPE
STORAGE.
Unusual Fire/Explosion Hazard:CADMIUM FUMES MAY BE RELEAASED DURING
BURNING.

Accidental Release

Spill Release Procedures:ELECTROLYTE,POTASSIUM HYDROXIDE,IS CAUSTIC.DO
NOT ALLOW SKIN/EYE CONTACT.FLUSH W/WATER.THERE'S ONLY A TRACE AMT
OF POTASSIUM HYDROXIDE AVAILABLE IN BATTERY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT INCINERATE OR MUTILATE;MAY
BURST RELEASING TOXIC MATL.(CADMIUM FUMES).DO NOT SHORT CIRCUIT
BATT,IT MAY CAUSE BURNS WHEN IN CONTACT W/SKIN/EYES.
Other Precautions:NOTE:ALEXANDER MFG CO CONSIDERS BATT ARTICLE AS
DEFINED IN 29CFR1910-1200 SEC(C).FURTHER ARTICLE(BATT)DOESNT
RELEASE/OTHERWISE RESULT IN EXPO TO HAZ CHEM UNDER CONDITIONS OF
INTENDED USE.EA CELL OF BA TT IS SEALED CNTNR ENCLOSING (SUPPLEMEN)

Exposure Controls

Supplemental Safety and Health
OTHER PRECAUT:NICKEL ELECTRODE,CADMIUM ELECTRODE & POTASSIUM HYDROXIDE
ELECTROLYTE.

Chemical Properties

HCC:Z5
Decomp Temp:Decomp Text:NP
Vapor Pres:N/AVAI
Vapor Density:NP
Spec Gravity:N/AVAI
pH:NP
Viscosity:NP
Evaporation Rate & Reference:NP
Solubility in Water:NA
Percent Volatiles by Volume:NP
Corrosion Rate:NP

Stability

Stability Indicator/Materials to Avoid:YES
NO INFO AVAILABLE.
Stability Condition to Avoid:BURNING (FIRE), RUPTURING.
Hazardous Decomposition Products:CADMIUM FUMES MAY BE RELEASED DURING
FIRE.

Disposal

Waste Disposal Methods:DISPOSE OF ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.